SERVICE MANUAL
LN-9248-05.3
(Replaces LN-9248-05.2)
March - 2013
MODEL: A11515-XXXXX
IMPORTANT: Before using this equipment,
carefully read SAFETY PRECAUTIONS, starting
on page 1, and all instructions in this manual.
Keep this Service Manual for future reference.
Service Manual Price: €25.00 (Euro)
$30.00 (U.S.)
PULSETRACK
SPEED CONTROL AND
MONITOR SYSTEM
Ransburg
Page view 0
1 2 3 4 5 6 ... 57 58

Summary of Contents

Page 1 - Ransburg

SERVICE MANUALLN-9248-05.3(Replaces LN-9248-05.2)March - 2013 MODEL: A11515-XXXXXIMPORTANT: Before using this equipment, carefully read SAFETY PRECAU

Page 2 - this manual

INTRODUCTIONGENERAL DESCRIPTIONThe PulseTrack 2TM system is designed to contin-uously monitor and maintain the program-mable speed of up to six rotary

Page 3 - CONTENTS

pneumatic pressure signal by the I/P transducer. The pneumatic signal is then supplied to a 1:1 air piloted regulator (volume booster) located near t

Page 4 - CONTENTS (Cont.)

SPECIFICATIONS Operating Temperature: 0°C to 50°C Storage Temperature: -20°C to 85°C Humidity: 0 to 95% non-condensing Size: 20" H x 16&qu

Page 5 - SAFETY PRECAUTIONS

Figure 1: Typical Turbodisk 2 Installation With Temperature Humidity Cards

Page 6 - Fire Hazard

ELECTRICAL NOISEElectrical noise refers to stray electrical signals in the atmosphere at various signal strengths and frequencies that can affect the

Page 7

INSTALLATIONLOCATIONControl Panel> The PulseTrack 2 Control Panel MUST be located outside the hazardous area (see NFPA-33).> This manual MUST be

Page 8

Figure 3: Optional Brake Control Valve Assembly (Bell Systems Only)TB3-NTB3-LTB3-GroundTABLE 1 - AC INPUT POWER CONNECTIONSDescriptionAC NeutralAC Li

Page 9

FIBER OPTIC CABLE (See Figure 5)Remove the tting from the ber optic input port (FO1 - FO6) on the side of the control panel and slide over one end o

Page 10 - INTRODUCTION

Supply AirUsing the supplied 3/8" OD tubing connect the Supply air inlet to a source of clean, dry factory air having an operating pressure of 80

Page 11 - Brake Air Valves (Optional)

Factory Air (clean and dry)Rotator 1 Volume Booster PilotRotator 2 Volume Booster PilotRotator 3 Volume Booster PilotRotator 4 Volume Booster PilotRot

Page 12 - SPECIFICATIONS

NOTE: This manual has been changed from revision LN-9248-05.2 to revision LN-9248-05.3. Reasons for this change are noted under “Manual Change Summa

Page 13

ELECTRICAL I/O (See Table 5)Electrical I/O terminals are available from a breakout board inside the PulseTrack 2 control Panel (see Figures 6 and 7).

Page 14 - ELECTRICAL NOISE

Figure 6: Electrical I/O Breakout Terminal Locations

Page 15 - INSTALLATION

Figure 7: Control Panel Schematic

Page 16 - INPUT POWER

Figure 8: Electrical I/O ConnectorsFigure 9A: Cable Grommet HardwareFigure 9B: Stripping Of I/O Cable

Page 17 - CONNECTIONS

4mA4.8mA5.6mA6.4mA7.2mA8.0mA8.8mA9.6mA10.4mA11.2mA12.0mA12.8mA13.6mA14.4mA15.2mA16.0mA16.8mA17.6mA18.4mA19.2mA-20mATABLE 3 - INPUT SIGNALS FOR GIVEN S

Page 18

Enable InputsDiscreet enable inputs are available for rotators 1 through 6 to interlock the speed control with aremote signal. This can be done pneum

Page 19

Master Overspeed OutputA 24VDC discreet output exists at breakout terminal J3-C23 to indicate when an overspeed fault occurs on any rotator. Us

Page 20 - ELECTRICAL I/O

Rotator 5 Enable InputRotator 6 Enable InputMaster Enable InputMaster Reset InputSlot 7 Temperature InputSlot 6 Temperature InputSlot 5 Temperature In

Page 21

Figure 10: Control CardDIP SWITCH SETTINGSControl CardThere is an 8 position dip switch SW1 located near the bottom of the control card (see Figure 1

Page 22

Dip Switch SW1-7This dip switch is used in conjunction with board jumpers E1-E6 to set the mode of the analog speed outputs. This is described previo

Page 23

SAFETY:SAFETY PRECAUTIONS...HAZARDS / SAFEGUAR

Page 24 - Analog Speed Setpoint Inputs

>The AC power must be cycled for the new dip switch setting to be recognized.NOTETemperature/Humidity CardThere is also a 4 position dip switch SW2

Page 25

OPERATIONTHEORY OF OPERATIONSpeed ControlWhen the rotator is spinning, the ber optic cable sends pulses of light back to the Fiber Optic Re-ceiver Mo

Page 26 - TABLE 5 - ELECTRICAL I/O

Figure 12: Front Panel Operating ControlsATOMIZER CARD CONTROLS(See Figure 13)Atomizer Speed DisplayThis two digit display indicates rotator speed in

Page 27

Local/Remote SwitchWhen the local/remote switch is in the local posi-tion, the setting on the Speed Select Thumbwheel switch is used to determine the

Page 28 - DIP SWITCH SETTINGS

TO ENABLE SPEED CONTROLTo enable speed control, rst make sure the Pulse-Track 2 is installed as detailed in the "Installation" section of t

Page 29 - W A R N I N G

3. Turn the front panel Master Control Switch to the STOP position or deactivate the electrical master enable input (see "Electrical I/O" in

Page 30 - Rotary DIP Switch

To Reset a FaultFaults can be reset using any of the following methods:1. Press the Master Reset Switch located on the front panel.2. Activate the m

Page 31 - OPERATION

MAINTENANCEGENERALDeveloping a good preventive maintenance (PM) program is key to keeping any system operating properly, the frequency of which is det

Page 32 - CONTROLS

3. Open the small glass door and loosen the mounting screws on the front of the card.4. Remove the card from the unit and reinstall the new card in r

Page 33 - HUMIDITY CARD

Figure 15: AC Line Filter (Top View)24VDC Power Supply (refer to Fig-ures 6, 18, and 19) 1. Turn off AC Power to the control panel at the Fused Disc

Page 34 - TO DISABLE SPEED

PARTS IDENTIFICATION:45-52CONTROL PANEL - FRONT VIEW / PARTS LIST...CONTROL PANEL - IN

Page 35 - FAULT DESCRIPTIONS

Fiber Optic Receiver Module1. Turn off AC Power to the control panel at the Fused Disconnect and open the cabinet door.2. Mark the ber optic cables

Page 36 - To Reset a Fault

Brake Solenoid (bells only - refer to Figures 6, 16, and 19)1. Turn off AC Power to the control panel at the Fused Disconnect and open the cabinet do

Page 37 - MAINTENANCE

TROUBLESHOOTING> Field repair and troubleshooting of the PulseTrack 2 Control Panel may require exposure to potentials that can cause SERIOUS BODIL

Page 38 - Front Panel Bulbs, Switches

Overspeed (oS) Fault:1. The braking air solenoid is not functioning properly.2. The brake air line has lost connection to the rotator.3. The brake a

Page 39

(Continued On Next Page)TROUBLESHOOTING GUIDEGeneral Problem Procedure SolutionNo Power(Green Power Switch Light Does Not Come On and Displays Are Bla

Page 40

TROUBLESHOOTING GUIDE (Cont.)(Continued On Next Page)General Problem Procedure SolutionMASTER RUN Switch Is Turned To RUN, But The Rota-tor(s) Do Not

Page 41 - Brake Solenoid (bells only

(Continued On Next Page)TROUBLESHOOTING GUIDE (Cont.)General Problem Procedure SolutionUNDERSPEED Fault (uS) (Cont.)OVERSPEED Fault (oS)LOSS OF FEED

Page 42 - BASIC SYSTEM

TROUBLESHOOTING GUIDE (Cont.) (Continued On Next Page)General Problem Procedure SolutionLOSS OF FEEDBACK Fault (LF) (Cont.)Invalid Speed Request Faul

Page 43 - (Temperature/Humidity Card):

TROUBLESHOOTING GUIDE (Cont.)General Problem Procedure SolutionAnalog Inputs or Outputs Not Working ProperlyNo Connection Fault (nc) - Temperature/Hum

Page 44 - TROUBLESHOOTING GUIDE

PARTS IDENTIFICATIONFigure 17: Control Panel - Front View

Page 45 - TROUBLESHOOTING GUIDE (Cont.)

W A R N I N G!W A R N I N G!SAFETYSAFETY PRECAUTIONSBefore operating, maintaining or servicing any Ransburg electrostatic coating system, read and u

Page 46

1 A11515-XXXXX PulseTrack 2 Speed Control and Monitor System Atomizer Card: 2 A11448-00 For A11515-XXX1X, 6" Conical Disk

Page 47

Figure 18: Control Panel - Inside Door View

Page 48

19 A11471-00 Ribbon Cable Assembly 20 LSME0013-00 Block Holder, Single SW2, SW3, R 21 LS

Page 49 - PARTS IDENTIFICATION

Figure 19: Control Panel - Inside Cabinet View

Page 50 - Part # Description Notation

25 4131-11 Fuse, 3A, 250V, Time Delay, 3AG, for A11515-XX0XX, 120 VAC Input F1, F2 4131-03 Fuse, 1.5A, 250V, Time Delay, 3AG,

Page 51

Item #RECOMMENDED SPARE PARTS LISTPart # Description1-4 4+Total # of Control Panels * See previous parts lists for proper dash numbers. 2 A11448-XX*

Page 52

WARRANTY POLICIESLIMITED WARRANTYRansburg will replace or repair without charge any part and/or equipment that falls within the specied time (see bel

Page 53

MANUAL CHANGE SUMMARYThis manual was published to replace Service Manual LN-9248-05.2 PulseTrack 2 Speed Control and Monitor System, to make the fol-l

Page 54 - (Figure 19)

Form No.LN-9248-05.3Litho in U.S.A.03/13© 2013 Ransburg. All rights reserved.Models and specications subject to change without notice.Manufacturing1

Page 55 - RECOMMENDED SPARE PARTS LIST

Spray AreaAREATells where hazards may occur.HAZARDTells what the hazard is.SAFEGUARDSTells how to avoid the hazard.Fire HazardImproper or inadequate o

Page 56 - WARRANTY POLICIES

AREATells where hazards may occur.HAZARDTells what the hazard is.SAFEGUARDSTells how to avoid the hazard.Spray AreaImproper operation or mainte-nance

Page 57 - MANUAL CHANGE SUMMARY

AREATells where hazards may occur.HAZARDTells what the hazard is.SAFEGUARDSTells how to avoid the hazard.Spray Area / High Voltage EquipmentElectrical

Page 58 - $30.00 (U.S.)

Toxic SubstancesCertain material may be harmful if inhaled, or if there is contact with the skin.Follow the requirements of the Material Safety Data S

Comments to this Manuals

No comments